Riester USA
Riester RVS-100 model 1960-RMBPU Vital Signs Monitor with NIBP, Masimo SpO2, Temp, Printer, US-plug (base unit)
- SKU:
- RIE 1960-RMBPU
- MPN:
- 1960-RMBPU
- Shipping:
- Calculated at Checkout
Description
Product Details
- 3 measurement modes (Monitor, Spot-check, Triage)
- High-sensitivity 8” TFT colour touch screen with self-explanatory user interface and integrated help- function
- Displays SYS, DIA, MAP, Pulse, Temp, Plethysmogram
- Clinical grade NIBP* including averaging mode
- Programmable NIBP averaging mode (2-5 readings)
- Riester, Masimo* or Nellcor* Oximax SpO2
- Predictive Thermometer (Filac 3000)
- Connectivity with the EMR - follows the HL7 standard
- LAN Connectivity as standard
- Programmable alarms (audible, visible) with 3 priority levels
- Supports nurse call RJ11 port
- Available as wall, desk and floor model
- Can be expanded to wall diagnostic station
- Internal memory for 5,000 measurements
- Lithium-ion battery with up to 17 hours ON time
(*includes neonate mode)
Options
- Barcode reader
- Mobile stand including basket for storage (cuffs, sensors, cables)
- WiFi
Accessories supplied with monitor
- NIBP extension tube
- 2 cuffs (adult & adult large incl. connectors)
- SpO2 sensor adult
- SpO2 extension cable
- Oral temperature probe
- Probe cover
- Thermal printer (internal)
Technical Data
Monitor
Power Supply: 100 – 240 V AC, 50/60 Hz
Battery: Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh,
Charging time to a 100%: 6 hours,
Operating time approx. 11 hours (new and fully charged battery at 25°C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval))
Low battery indicator
Charging battery indicator
Dimensions Monitor: L x H x W: 303 x 230 x 110 mm (11.93 x 9.06 x 4.33 in)
Weight: 3.60 kg (7.94 lb) including temp module, printer
Dimensions Basket: L x H x W: 270 x 225 x 200 mm (10.63 x 8.86 x 7.88 in)
Alarm:
Visible LEDs (Yellow, Red, Blue, Green, Orange)
Audible Speaker
Gives audible alarm, QRS tone
Supports Pitch Tone and multi-level volume
Alarm tones meet the requirement of IEC 60601-1-8.
Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone.
Ports:
1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15V/1.2 A Clinical-grade NIBP (non-invasive blood pressure)
Clinical-grade NIBP (non-invasive blood pressure)
Measuring method: automatic oscillometric
Measurement range:
Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg
Pediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg
Neonate SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg
Cuff pressure range: 0 – 280 mmHg
Resolution: 1 mmHg
Pressure accuracy:
Static ±3 mmHg
Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range: 40 – 240 bpm
Pulse rate accuracy: 1 bpm
Initial inflation pressure:
Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software)
Adult 297 ± 3 mmHg, Pediatric 252 ± 3 mmHg, Neonate 147 ± 3 mmHg
Alarm range:
SYS 0 – 300 mmHg
DIA 0 – 300 mmHg
MAP 0 – 300 mmHg
Riester SpO2
Measurement range: 0 – 100%
Resolution: 1%
Accuracy: ±2% (70 to 100%)
±3% (40% to 69%)
Unspecified (0% to 39%)
Alarm range: 0 – 100%
Average time: 4 sec, 8 sec, 16 sec
Pulse rate
Measurement range: 20 – 250 bpm
Resolution: 1 bpm
Accuracy: ±1% or ±1 bpm whichever is greater
Nellcor SpO2
Measurement range: 0-100%
Resolution: 1%
Accuracy: 70 – 100%: ±2% (adult, pediatric)
70 – 100%: ±3% (neonate)
Unspecified (0 – 69%)
Alarm range: 0 – 100%
Average time: 8 sec, 16 sec
Pulse rate
Measurement range: 20 – 300 bpm
Resolution: 1 bpm
Accuracy: 20 – 250 bpm: ±3 bpm
251 – 300 bpm: unspecified
Masimo SpO2
Measurement range: 0 – 100%
Resolution: 1%
Accuracy: 70 – 100%: ±2% (adult, pediatric, non-motion conditions)
70 – 100%: ±3% (neonate, non-motion conditions)
70 – 100%: ±3% (motion conditions)
0 – 69%: unspecified
Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate
Measurement range: 25 – 240 bpm
Resolution: 1 bpm
Accuracy: ±3 bpm (non-motion conditions)
±5 bpm (motion conditions)
Predictive thermometer
Oral ( Quick Mode )
non-fever temps: 3-5 seconds
fever temps: 8-10 seconds
Oral ( Standard Mode ): 6-10 seconds
Axillary Mode: 8-12 seconds
Rectal Mode: 10-14 seconds
Direct Mode (all sites): 60-120 seconds
Measurement accuracy: 35.5ºC - 42ºC (95.9°F – 107.6°F)
Direct Mode (all sites): ±0.1ºC (±0.2ºF)
Standard Prediction Mode (all sites): ±0.1ºC (±0.2ºF)
Quick Prediction Mode (oral only): ±0.3ºC (±0.5ºF)